Intricately designed to bring water temperature to the desirable level, HeatFirst as a brand upholds durability standards, increased comfort and environmental consciousness. Both for condominium and commercial settings, its built-in state of the art Scroll compressor operate at high efficiency with low noise and vibration levels. Each unit is completely erosion resistant since housed in a 100% stainless steel enclosure making it a flexible installation. Condensate drain connection and multiple rows of copper tubes produce high temperature water.

The propeller fans are directly driven operation at no less than 1100rpm or 50Hz. The stainless steel water pump is capable of high flow rates. The Air-source pump extracts the humidity and surrounding heat from the air or open space.

The long lasting product range comprises of the following models:

For Condominium arrangements
Model

System Description

Hot Water Consumption
HRM – 200LTank Capacity 200L, Dimension (560mm x 1830), Weight (full 278kg), Tank material (premium grade stainless steel) , Insulation( high pressure polyurethane foam),Electric booster 2kw, Power 20Amp, fully operation Amperage 6.4 x 
HRM – 250LRated heating capacity 5, Maximum outlet temperature 60Celsius, Power supply 240V, Speed of Fan( 950RPM), Noise level 51 dB(A), Dimension(600mm x 1925), Weight 333kg, Hot and cold water connection (3/4 inch BSP), Safety Valve and drainage (3/4inch BSP), Refrigerant ( R410A), Rotary Compressor, Co-efficient of Permission ( 3.8- 4.2), Tank material( premium grade stainless steel), Insulation(high pressure polyurethane foam), Electric booster 2kw, Power 20Amp.6 x 
HRM – 300LDimension (640mm x1820mm), Weight (389 kg), Inner Tank Material is Premium Grade Stainless Steel, External Tank Material is Stainless Steel, Tank Insulation is High Pressure Injected Polyurethane Foam 45kG/m3, Standby Electric Booster(2 kw), Incoming Power Requirement is 20 Amp, Full Operation Amperage 6.8 x 
MP

For Condominium arrangements
Model

System Description

Hot Water Consumption
MP-200GCapacity; Liter 908 & Imp Gal 200, Outer Dimension (1000mm x1680mm), Weight Empty (246), Weight Operating (1155).20 x 
MP-300GCapacity; Liter 1362 & Imp Gal 300, Outer Dimension (1000mm x 2480mm), Weight Empty (333), Weight Operating (1696).30 x 
MP-400GCapacity; Liter 1816 & Imp Gal 400, Outer Dimension (1400mm x1890mm), Weight Empty (398), Weight Operating (2216).40 x 
MP-500GCapacity; Liter 2270 & Imp Gal 500, Outer Dimension (1400mm x 2280mm), Weight Empty (446), Weight Operating (2737).50 x 
MP-700GCapacity; Liter 3178 & Imp Gal 700, Outer Dimension (1700mm x 2050mm), Weight Empty (605), Weight Operating (3783).70 x 
MP-800GCapacity; Liter 3632 & Imp Gal 800, Outer Dimension (1700mmx 2450mm), Weight Empty (654), Weight Operating (4286).80 x 
MP-900GCapacity; Liter 4086 & Imp Gal 900, Outer Dimension (1700mm x 2650mm), Weight Empty (703), Weight Operating (4790).90 x 
MP-1000GCapacity; Liter 4540 & Imp Gal 1000, Outer Dimension (1700mm x 2850mm), Weight Empty (755), Weight Operating (5301).125 x 
MP-1250GCapacity; Liter 5680 & Imp Gal 1250, Outer Dimension (1985mm x 2550mm), Weight Empty (1550), Weight Operating (6870).110 x 
MP-1500GCapacity; Liter 6810 & Imp Gal 1500, Outer Dimension (1985mm x 2980mm), Weight Empty (1275), Weight Operating (8092).150 x 
MP-1750GCapacity; Liter 7945 & Imp Gal 1750, Outer Dimension (1985mm x 3360mm), Weight Empty (1605), Weight Operating (9559).175 x 
MP-2000GCapacity; Liter 9080 & Imp Gal 2000, Outer Dimension (1985mm x 3750mm), Weight Empty (1960), Weight Operating (11050).200 x 

Above mentioned models can have other specific capacities can be made to order.
Model

System Description

Hot Water Consumption
HF-15Heating Capacity (15kW and 51195Btu/hr), Capacity to cool (11.2kW and 3.2 Tons), C.O.P (4), Refrigerant (R134a), Dimension (1200mm x1180mm x 750mm, LxHxB), Weight (225kg).40 x 
HF-22Heating Capacity (22.5kW and 76750Btu/hr), Capacity to cool (16.5kW and 4.7 Tons), C.O.P (4), Refrigerant (R134a), Dimension (1200mm x1180mm x 750mm,LxHxB), Weight (285kg).50 x 
HF-30Heating Capacity (30 kW and 102390 Btu/hr), Capacity to cool (22.8 kW and 6.5 Tons), C.O.P (4), Refrigerant (R134a), Dimension (1380mm x 1180mm x 850mm, LxHxB), Weight (330 kg).60 x 
HF-45Heating Capacity (45kW and 153585 Btu/hr), Capacity to cool (33.3kW and 9.5 Tons), C.O.P (4), Refrigerant (R134a), Dimension (1380mm x 1180mm x 850mm, LxHxB), Weight (370 kg).70 x 
HF-60Heating Capacity (60kW and 204780 Btu/hr), Capacity to cool (43.8kW and 12.4 Tons), C.O.P (4), Refrigerant (R134a), Dimension (1380mm x 1180mm x 850mm, LxHxB), Weight (415 kg).80 x 
Click number below to get FREE Quote
or

Call us now!

010-6667431

1 Comment

Comments are closed.